Skip to content

Calibration doesn't give same résult with different board #3

@CedricCourson

Description

@CedricCourson

Hello
I'm trying to understand why the calibration function give very different result with different board ....

for exemple :

Variable | ESP32 | Arduino UNO | Arduino nano

H1Tmag | 85176.98 | 9455.57 | 0
High Mag 1 | Found | Found | Found
H2mag | 91897.48 | 970.20 | 0
High Mag 2 | Found | Found | Found
Calibration | done | done | done
GF_high |-0.00000134 | 0.0000016 | inf
Nos_High | 92644.2031 | 27.38 | 0

Admittance | 0 | 22.290 | nan

Thank you